Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles

Sridhar Sundarama*, Utkarsh Chhanchurea*, Prachi Patila, Vishal Setha, Akhil Mahajana, Munita Balb, Rajiv Kumar Kaushalb, Mukta Ramadwarb, Neelam Prabhudesaic, Manish Bhandared, Shailesh V. Shrikhanded, Shaesta Mehtaa

Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, India

aDepartment of Digestive Diseases and Clinical Nutrition (Sridhar Sundaram, Utkarsh Chhanchure, Prachi Patil, Vishal Seth, Akhil Mahajan, Shaesta Mehta); bDepartment of Pathology (Munita Bal, Rajiv Kumar Kaushal, Mukta Ramadwar); cDepartment of Cytopathology (Neelam Prabhudesai); dDepartment of Surgical Oncology (Manish Bhandare, Shailesh V. Shrikhande), Tata Memorial Hospital, Mumbai, India

Correspondence to: Sridhar Sundaram, MD, DM (Gastroenterology), Associate Professor, Department of Digestive Diseases and Clinical Nutrition, Tata Memorial Hospital, Homi Bhabha National Institute, Dr. E Borges Road, Parel, Mumbai 400012 India, e-mail: drsridharsundaram@gmail.com/drsridharsundaram@kem.edu
* Co-first authors

Part of this study was presented at United European Gastroenterology Week 2022

Received 15 November 2022; accepted 23 January 2023; published online 04 April 2023
DOI: https://doi.org/10.20524/aog.2023.0790
© 2023 Hellenic Society of Gastroenterology

Abstract

Background Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the same needle.

Methods Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-FNB of pancreatic solid lesions between January 2021 and July 2022 were included. Demographic details, site and size of lesion, number of passes, and the diagnosis by cytology and histopathology of core tissue were noted. The first pass was used for ROSE adequacy assessment and was subsequently sent for cytological assessment. Additional passes were taken subsequently to acquire core tissue. Adequacy was confirmed by MOSE (whitish core of more than 4 mm). Final cytology and histopathology (HPE) were compared for diagnostic accuracy.

Results One hundred fifty-five patients were included in the analysis during the study period (mean age 55.1+12.9 years; 60% male; 77% in pancreatic head; median size 3.7 cm). The final diagnosis was malignancy in 129, while 26 were negative for malignancy. Sensitivity and specificity for ROSE with cytology in detecting malignant SPLs were 96.9% and 100%, respectively. HPE with MOSE had sensitivity and specificity of 96.1% and 100%, respectively. A comparison of diagnostic accuracy showed no significant difference (P>0.99) between HPE with MOSE and ROSE with cytology, using an FNB needle.

Conclusion MOSE is as good as ROSE in terms of diagnostic yield for solid pancreatic lesions sampled using newer-generation EUS biopsy needles.

Keywords Endoscopic ultrasound tissue acquisition, rapid on-site evaluation, macroscopic on-site evaluation, pancreatic cancer, diagnostic accuracy

Ann Gastroenterol 2023; 36 (3): 340-346


Introduction

Linear endoscopic ultrasonography (EUS) creates real-time images of the digestive tract and adjacent lesions, allowing the identification of suspected malignancies [1]. EUS-guided fine needle aspiration (FNA) offers an opportunity for sampling mediastinal, intraabdominal, and pancreatic lesions under direct visualization [2]. EUS-FNA is a safe, well-established, and first-line diagnostic tool for the evaluation of solid pancreatic lesions [3]. Its sensitivity and specificity have been reported to be 86.8% and 95.8%, respectively [4]. Solid pancreatic lesions are most commonly pancreatic adenocarcinomas (PAC), followed by neuroendocrine tumors (NET), and solid pseudopapillary tumors (SPT) [5]. PAC remains one of the most lethal malignancies, with a dismal prognosis and a 5-year survival rate of 5-20% [6,7]. Solid pancreatic lesions may often be secondary to benign pathology. In a previous series, 6.5% of 446 patients who underwent surgery for pancreatic solid lesions had an underlying benign etiology [8]. Hence, tissue diagnosis remains critical in situations with a diagnostic dilemma, while in patients where neoadjuvant therapy is planned, sampling of pancreatic solid lesions to confirm diagnosis is recommended [9].

Despite controversial results in various meta-analyses [10-13], rapid on-site evaluation (ROSE) has the persuasive advantages of providing timely feedback on sample adequacy and optimizing the number of needle passes required to make a diagnosis using EUS-guided sampling. Cytopathologists aid the procedure by indicating when an adequate specimen has been obtained, thereby ensuring maximal yield with the minimum number of passes, as well as assisting with sample triage for ancillary studies, such as microbiology and flow cytometry, as needed. However, the availability of ROSE in tertiary care centres and, even more importantly, in community hospitals is limited because of the complexity of expertise development and related costs [14].

Efforts have been made to succeed in acquiring samples for histologic evaluation to overcome the limitations of ROSE [15]. The newest generation of histology needles has recently become available, divided into those with a modified tip with cutting edges and those with a forward-facing bevel on a side fenestration. All these needles have demonstrated a better histologic and diagnostic yield compared with standard FNA needles [16-18]. EUS-guided fine needle biopsy (EUS-FNB) has a diagnostic yield equal to that of EUS-FNA+ROSE [19-21]. Macroscopic on-site evaluation was first described by Iwashita et al in 2015 to assess the adequacy of core tissue using 19-G FNA needles [22]. Now, MOSE has been increasingly used to assess adequacy after EUS-guided sampling using FNB needles. We aimed to do a comparative assessment of the diagnostic yield of EUS-FNB with adequacy assessed by MOSE, and ROSE with cytology, performed using the same newer-generation EUS biopsy needle.

Materials and methods

Study design

This was a retrospective study of prospectively maintained endoscopy database at a tertiary care oncology centre in Western India. Data was retrieved from the endoscopy database and details were extracted from the electronic medical records with the help of the information technology department at our institute. Approval was obtained from the institutional ethics committee prior to commencing the project.

Patient population

Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-guided sampling of lesions between January 2021 and July 2022 were included. Patients who had a lesion likely to be visualized and sampled by EUS, and were able to provide informed consent, were included. Demographic details, details of site of lesion, size of lesion, number of passes, adequacy by ROSE, diagnosis as achieved by cytology and histopathologic assessment of core tissue were noted. Patients whose lesions had a cystic component were excluded.

EUS procedure and specimen processing

EUS was performed by 2 experts who had experience of more than 100 EUS procedures performed independently. Sampling was done using a 22-G AcquireTM (Boston Scientific, USA) needle in all cases, using the slow stylet pull-through method with fanning technique, with the patient under either conscious sedation or general anesthesia. A minimum of 2 passes, one for ROSE and other for core tissue sampling, were performed. The first pass was given for ROSE to assess for adequacy of smear cytology. Touch imprint cytology was taken for making smears for ROSE by a trained cytopathologist. The tissue was placed on a slide, and by gently pressing down and rubbing with another slide smears were made using the superficial imprints. Smears were stained with toluidine blue and were evaluated for adequacy under the microscope. This sample was subsequently sent to cytology for diagnosis if adequate. Those patients where ROSE was not performed or where core tissue was not taken for histopathology were excluded from the analysis. Additional passes were subsequently made to acquire core tissue from the solid masses. The adequacy of core tissue was confirmed by macroscopic on-site evaluation (MOSE) of a whitish core with length >4 mm. The specimen was expelled over a glass slide to assess adequacy. These samples were submitted for histopathologic examination (HPE) in formalin jars (Fig. 1).

thumblarge

Figure 1 Core tissue sent for histopathology

Outcome measures

The primary outcome measure was diagnostic accuracy, defined by the percentage of collected specimens matching the final diagnosis (Fig. 2 A-J). The final diagnosis was based on surgical specimen histopathology, or repeat computed tomography-guided sampling, and in the case of negative samples a clinical follow-up of up to 6 months to determine the nature of the disease. Accuracy was compared between the “ROSE with cytology” group and the “HPE with MOSE” group. Secondary outcome measures were the number of passes needed for ROSE adequacy, the total number of passes taken, and adverse events related to the procedure. Cytology and ROSE evaluations followed the Papanicolaou classification [23]. Adverse events were reported using the American Society for Gastrointestinal Endoscopy’s standard lexicon for endoscopic adverse events [24]. In patients with a negative sample, a repeat biopsy was performed if there was a high pretest probability of cancer. All patients with negative samples were followed-up with serial interval imaging at 3 and 6 months, as well as tumor markers.

thumblarge

Figure 2 (A-D) A spectrum of adenocarcinoma cases seen on cytology smears. (E-F) Invasive adenocarcinoma seen within a desmoplastic stroma. (G-H) Epithelioid granuloma along with inflammatory cells. (I) Well-differentiated neuroendocrine tumor seen in a hyalinized stroma. (J) Well-differentiated neuroendocrine tumor cells show immunoreactivity for synaptophysin

Sample size

Considering an accuracy of 95% both ROSE and MOSE, with a non-inferiority margin of 7%, the sample size would have to be 120 patients in each arm in order to achieve a statistical power of 80% within an error of 0.05. Since the study used paired sampling, a total of 120 patients needed to be enrolled.

Statistical analysis

The statistical analyses were performed using SPSS version 26.0 (IBM, Armonk, NY, USA). Continuous variables were represented as mean and median, with standard deviation and interquartile range, respectively. Categorical variables were represented as percentages. Comparison of diagnostic accuracy between both groups was done using McNemar’s test for paired nominal data.

Results

One hundred sixty-eight patients underwent EUS-guided sampling for SPLs during the study period. Of these, 13 patients either underwent only a single pass for ROSE or core tissue acquisition without ROSE, leaving 155 to be included in the final analysis. The mean age of the cohort was 55.1+12.87 years and 60% (93/155) were male. The majority of lesions were located in the head of the pancreas (77%). The mean largest dimension of lesions was 3.7 cm. The reason for sampling the lesion was its borderline resectable nature prior to neoadjuvant therapy in 75 (48.4%) patients, locally advanced unresectable disease in 48 (30.9%) patients, and to confirm the nature of the disease process (benign vs. malignant) in 32 (20.6%) patients.

ROSE with cytology was able to diagnose malignancy in 125 patients, and HPE with MOSE was able to diagnose malignancy in 124 patients. In 3 patients, diagnosis was achieved only by ROSE with cytology, while in 2 other patients it was achieved only by HPE with MOSE. In 2 patients, neither ROSE with cytology nor HPE with MOSE was able to diagnose malignancy. Sensitivity and specificity for malignant SPLs were 96.9% and 100%, respectively, for ROSE with cytology. Final histopathology of core tissue could diagnose malignant SPLs with sensitivity and specificity of 96.1% and 100% respectively. The overall accuracy of ROSE with cytology was 97.42% (95% confidence interval [CI] 93.53-99.29) while the accuracy for HPE with MOSE was 96.78% (95%CI 92.63-98.95). Comparison using the McNemar chi-square test for paired nominal data showed no significant difference (P>0.99) in accuracy between final HPE with MOSE and ROSE with cytology, when an FNB needle was used.

The median number of passes required overall was 3 (range 2-6): 2 passes were needed in 61 (39.4%) patients and 3 passes in 50 (32.3%). In 13 (8.3%) patients, more than one pass was required for confirming adequacy on ROSE. There was no correlation between the total number of passes and the size (Pearson correlation 0.160, P=0.235) or location (P=0.120) of the lesion (Fig. 1). No significant difference was seen in lesion size or location between those who required additional passes for ROSE and those who required only one pass (P=0.261). The final diagnosis was malignancy in 129 patients (adenocarcinoma 110, NET 14, solid pseudopapillary epithelial neoplasms 2, and lymphoma 3), whereas 26 were negative for malignancy (autoimmune pancreatitis 5, tuberculosis 5). Adverse events related to the procedure included perforation in one patient (Stapfer type 1), requiring surgical closure. A summary of these results is provided in Tables 1 and 2 and Fig. 3.

Table 1 Study characteristics

thumblarge

Table 2 Primary outcome measures

thumblarge

Figure 3 Graphical abstract for results

thumblarge

ROSE, rapid on-site evaluation; MOSE, macroscopic on-site evaluation; EUS, endoscopic ultrasound; FNB, fine-needle biopsy; PSLs, pancreatic sold lesions; HPR, histopathological examination report

Discussion

We found that when new-generation biopsy needles were used for the evaluation of SPLs, EUS-FNB alone, with adequacy assessed by MOSE, was not inferior to ROSE with cytology with respect to diagnostic accuracy. Until now, EUS-FNA+ROSE has been the preferred technique for EUS-guided tissue acquisition, with ROSE being an important factor affecting the diagnostic yield, as confirmed in a large randomized controlled trial with 351 patients [25]. Newly introduced needles specifically designed for EUS-FNB have recently achieved significantly better diagnostic accuracy than standard FNA needles. A large retrospective study of 2127 SPLs also confirmed the better accuracy [26]. A systematic review and meta-analysis by van Riet et al showed that for SPL sampling EUS-FNB had a higher diagnostic yield than EUS-FNA and required fewer passes [16]. A recent network meta-analysis comparing different needle types showed that end-cutting needles are best for EUS-guided sampling of pancreatic lesions, compared to FNA and side cutting needles [27]. We used only Franseen type end-cutting needles for EUS-FNB in our cohort to ensure homogeneity.

A multicenter retrospective study of EUS-guided sampling of SPLs with ROSE by De Moura et al revealed that EUS-FNB, either with ROSE or alone, was more accurate than EUS-FNA. EUS-FNB with ROSE had a higher diagnostic yield compared to FNB alone (93% vs. 88%) [28]. However, the authors did not mention how sample adequacy for EUS-FNB alone was measured. Moreover, there was a wide variation in needle size and type, with a large proportion of patients being sampled using a 25-G needle. Only one previous multicenter randomised controlled trial (RCT) by Crino et al showed that EUS-FNB was non-inferior to EUS-FNB with ROSE, having an accuracy >95% [29]. However, that RCT had some issues with respect to inhomogeneity in the type of needle and the technique used for sampling (wet-suction, dry-suction or slow stylet pull-through). Furthermore, the adequacy of the FNB was not assessed and a minimum of 3 passes were performed. Studies suggest that MOSE has a high overall diagnostic accuracy of >90% and can be considered as a tool to increase the diagnostic yield of PSL specimens [30,31]. In our study, unlike previous comparative studies, we assessed the adequacy of EUS-FNB alone using MOSE. In addition, we used the slow stylet pull-through technique with Franseen needles in all patients, ensuring uniformity. Our accuracy was more than 95%, in line with previous studies.

Previous studies suggest that fewer passes are needed per patient when ROSE is used [32,33]. In our study, the median number of passes including ROSE were 3, with most patients needing only one pass for ROSE and 2 passes for FNB. Tumor characteristics (size or site) did not affect the overall number of passes needed for diagnosis. The European Society of Gastrointestinal Endoscopy’s guidelines, published in 2017, refer to a minimum of 2-3 passes with an FNB needle for solid lesions, with or without on-site cytopathology [34]. A previous study from Greece suggested that the overall diagnostic yield is similar in those who undergo 2 or 3 passes in the absence of ROSE [35]. The recommendations and findings of that study are similar to our own, where the majority needed 2 or 3 passes overall. Our rate of adverse events was low, in accordance with the literature and the standard guidelines [36].

The logistic constraints imposed by ROSE may have limited the use of EUS-guided sampling. Centers should give careful consideration to the need for ROSE and to whether adequate accuracy is achieved with MOSE alone [37]. Core tissue acquisition in patients with pancreatic ductal adenocarcinoma may help in molecular stratification and molecular profiling, which may impact therapeutic stratification [38]. Assessment of the Ki-67 index on core tissue specimens is critical for stratification in NET, and is more reliable than cytology specimens [39]. The sampling procedure is significantly shorter in the absence of ROSE, with a mean difference of about 6 min in favor of EUS-FNB alone [29]. This is particularly beneficial for high-volume units to optimise patient flow. In their RCT, Oppong et al also demonstrated a shorter pathology viewing time for histologic compared with cytologic samples, suggesting that EUS-FNB with off-site histologic evaluation can be time-saving and cost-effective, especially in high-volume centers [18].

Our study has several strengths, notably the uniformity in the choice of needle in terms of size and type, and the suction technique. We evaluated the adequacy of FNB alone using MOSE, thus eliminating the need for a fixed number of passes as in previous studies. To our knowledge, no previous trials have compared ROSE and MOSE. We used paired testing, which reduces selection bias. Apart from its strengths, our study also had a few limitations, which include its retrospective nature and the fact that only 2 experienced endoscopists performed all the procedures, making it difficult to generalize our findings.

To conclude, EUS FNB alone with MOSE has a high diagnostic accuracy for SPLs. ROSE does not increase the diagnostic yield for SPLs sampled using newer-generation EUS biopsy needles. The utility of ROSE should be reviewed, considering its extra costs and logistics.

Summary Box

What is already known:


  • Endoscopic ultrasound (EUS)-guided sampling of solid pancreatic lesions (SPLs) is highly accurate using fine needle aspiration (FNA) needles and rapid on-site evaluation (ROSE)

  • Core biopsy needles increase tissue yield, with adequacy of the core assessed using macroscopic on-site evaluation (MOSE)

  • Tissue obtained using core biopsy needles with a fixed number of passes (n=3) gives similar accuracy as FNA with ROSE

What the new findings are:


  • No previous studies have compared the diagnostic accuracy of EUS sampling of SPLs with adequacy of core tissue assessed by MOSE, vs. cytological assessment with ROSE, performed using core biopsy needles

  • MOSE and ROSE can both assess the adequacy of sampling, without any difference in overall diagnostic accuracy for SPLs

  • There is need to reevaluate ROSE while using core biopsy needles with respect to cost and logistics

References

1. Strand DS, Jeffus SK, Sauer BG, Wang AY, Stelow EB, Shami VM. EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms. Diagn Cytopathol 2014;42:751-758.

2. Weston BR, Bhutani MS. Optimizing diagnostic yield for EUS-guided sampling of solid pancreatic lesions:a technical review. Gastroenterol Hepatol (N Y) 2013;9:352-363.

3. Tharian B, Tsiopoulos F, George N, Pietro SD, Attili F, Larghi A. Endoscopic ultrasound fine needle aspiration:Technique and applications in clinical practice. World J Gastrointest Endosc 2012;4:532-544.

4. Puli SR, Bechtold ML, Buxbaum JL, Eloubeidi MA. How good is endoscopic ultrasound-guided fine-needle aspiration in diagnosing the correct etiology for a solid pancreatic mass?:A meta-analysis and systematic review. Pancreas 2013;42:20-26.

5. Santo E, Bar-Yishay I. Pancreatic solid incidentalomas. Endosc Ultrasound 2017;6:S99-S103.

6. Bray F, Ferlay J, Soerjomataram I, Siegel RL, Torre LA, Jemal A. Global cancer statistics 2018:GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2018;68:394-424.

7. Ferlay J, Ervik M, Lam F, et al. Global Cancer Observatory:Cancer Today. Lyon, France:IARC, 2018. Available from:https://gco.iarc.fr/today/home [Accessed 9 March 2023].

8. Gomes RM, Bal M, Patkar S, Goel M, Shrikhande SV. Unexpected benign histopathology after pancreatoduodenectomy for presumed malignancy:accepting the inevitable. Langenbecks Arch Surg 2016;401:169-179.

9. Asbun HJ, Conlon K, Fernandez-Cruz L, et al;International Study Group of Pancreatic Surgery. When to perform a pancreatoduodenectomy in the absence of positive histology?A consensus statement by the International Study Group of Pancreatic Surgery. Surgery 2014;155:887-892.

10. Kong F, Zhu J, Kong X, et al. Rapid on-site evaluation does not improve endoscopic ultrasound-guided fine needle aspiration adequacy in pancreatic masses:a meta-analysis and systematic review. PLoS One 2016;11:e0163056.

11. Hébert-Magee S, Bae S, Varadarajulu S, et al. The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma:a meta-analysis. Cytopathology 2013;24:159-171.

12. Matynia AP, Schmidt RL, Barraza G, Layfield LJ, Siddiqui AA, Adler DG. Impact of rapid on-site evaluation on the adequacy of endoscopic-ultrasound guided fine-needle aspiration of solid pancreatic lesions:a systematic review and meta-analysis. J Gastroenterol Hepatol 2014;29:697-705.

13. Hewitt MJ, McPhail MJ, Possamai L, Dhar A, Vlavianos P, Monahan KJ. EUS-guided FNA for diagnosis of solid pancreatic neoplasms:a meta-analysis. Gastrointest Endosc 2012;75:319-331.

14. van Riet PA, Cahen DL, Poley JW, Bruno MJ. Mapping international practice patterns in EUS-guided tissue sampling:outcome of a global survey. Endosc Int Open 2016;4:E360-E370.

15. RimbaşM, Crino SF, Gasbarrini A, Costamagna G, Scarpa A, Larghi A. EUS-guided fine-needle tissue acquisition for solid pancreatic lesions:finally moving from fine-needle aspiration to fine-needle biopsy?Endosc Ultrasound 2018;7:137-140.

16. van Riet PA, Larghi A, Attili F, et al. A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device. Gastrointest Endosc 2019;89:329-339.

17. Oppong KW, Bekkali NLH, Leeds JS, et al. Fork-tip needle biopsy versus fine-needle aspiration in endoscopic ultrasound-guided sampling of solid pancreatic masses:a randomized crossover study. Endoscopy 2020;52:454-461.

18. van Riet PA, Erler NS, Bruno MJ, Cahen DL. Comparison of fine-needle aspiration and fine-needle biopsy devices for endoscopic ultrasound-guided sampling of solid lesions:a systemic review and meta-analysis. Endoscopy 2021;53:411-423.

19. Chen YI, Chatterjee A, Berger R, et al. EUS-guided fine needle biopsy alone vs. EUS-guided fine needle aspiration with rapid on-site evaluation of cytopathology in pancreatic lesions:a multicenter randomized trial. Endoscopy 2022;54:4-12.

20. Khan MA, Grimm IS, Ali B, et al. A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy:diagnostic yield and the value of onsite cytopathological assessment. Endosc Int Open 2017;5:E363-E375.

21. Bang JY, Navaneethan U, Hasan MK, Hawes R, Varadarajulu S. Endoscopic ultrasound-guided specimen collection and evaluation techniques affect diagnostic accuracy. Clin Gastroenterol Hepatol 2018;16:1820-1828.

22. Iwashita T, Yasuda I, Mukai T, et al. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions:a single-center prospective pilot study (MOSE study). Gastrointest Endosc 2015;81:177-185.

23. Pitman MB, Layfield L. The Papanicolaou Society of Cytopathology system for reporting pancreaticobiliary cytology. Springer International Publishing, Switzerland, 2015, 6.

24. Cotton PB, Eisen GM, Aabakken L, et al. A lexicon for endoscopic adverse events:report of an ASGE workshop. Gastrointest Endosc 2010;71:446-454.

25. Bang JY, Hebert-Magee S, Navaneethan U, Hasan MK, Hawes R, Varadarajulu S. EUS-guided fine needle biopsy of pancreatic masses can yield true histology. Gut 2018;67:2081-2084.

26. Bang JY, Kirtane S, Krall K, et al. In memoriam:fine-needle aspiration, birth:fine-needle biopsy:the changing trend in endoscopic ultrasound-guided tissue acquisition. Dig Endosc 2019;31:197-202.

27. Gkolfakis P, CrinòSF, Tziatzios G, et al. Comparative diagnostic performance of end-cutting fine-needle biopsy needles for EUS tissue sampling of solid pancreatic masses:a network meta-analysis. Gastrointest Endosc 2022;95:1067-1077.

28. de Moura DTH, McCarty TR, Jirapinyo P, et al. Evaluation of endoscopic ultrasound fine-needle aspiration versus fine-needle biopsy and impact of rapid on-site evaluation for pancreatic masses. Endosc Int Open 2020;8:E738-E747.

29. CrinòSF, Di Mitri R, Nguyen NQ, et al. Endoscopic ultrasound-guided fine-needle biopsy with or without rapid on-site evaluation for diagnosis of solid pancreatic lesions:a randomized controlled non-inferiority trial. Gastroenterology 2021;161:899-909.

30. Leung Ki EL, Lemaistre AI, Fumex F, et al. Macroscopic onsite evaluation using endoscopic ultrasound fine needle biopsy as an alternative to rapid onsite evaluation. Endosc Int Open 2019;7:E189-E194.

31. Mangiavillano B, Frazzoni L, Togliani T, et al. Macroscopic on-site evaluation (MOSE) of specimens from solid lesions acquired during EUS-FNB:multicenter study and comparison between needle gauges. Endosc Int Open 2021;9:E901-E906.

32. Schmidt RL, Walker BS, Howard K, Layfield LJ, Adler DG. Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions:a risk-benefit analysis. Dig Dis Sci 2013;58:3280-3286.

33. Nebel JA, Soldan M, Dumonceau JM, et al. Rapid on-site evaluation by endosonographer of endoscopic ultrasound fine-needle aspiration of solid pancreatic lesions:a randomized controlled trial. Pancreas 2021;50:815-821.

34. Polkowski M, Jenssen C, Kaye P, et al. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology:European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017. Endoscopy 2017;49:989-1006.

35. Koukoulioti E, Tziatzios G, Tadic M, et al. Two needle passes achieve similar diagnostic yield compared to three passes regarding diagnosis of solid pancreatic lesions in endoscopic ultrasound-guided fine needle aspiration. Diagnostics (Basel) 2021;11:2272.

36. Forbes N, Coelho-Prabhu N, Al-Haddad MA, et al;ASGE Standards of Practice Committee. Adverse events associated with EUS and EUS-guided procedures. Gastrointest Endosc 2022;95:16-26.

37. Larghi A, Eguia V, Hassan C, Verna EC, Tarantino I, Gonda TA. Economic crisis:the right time to widen endoscopic ultrasound utilization. Endoscopy 2014;46:80-81.

38. Dreyer SB, Jamieson NB, Evers L, et al. Feasibility and clinical utility of endoscopic ultrasound guided biopsy of pancreatic cancer for next-generation molecular profiling. Chin Clin Oncol 2019;8:16.

39. CrinòSF, Ammendola S, Meneghetti A, et al. Comparison between EUS-guided fine-needle aspiration cytology and EUS-guided fine-needle biopsy histology for the evaluation of pancreatic neuroendocrine tumors. Pancreatology 2021;21:443-450.

Notes

Conflict of Interest: None